Quantum Data 802R Guia do Utilizador Página 518

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 517
508 Appendix A Command Reference
SCAN
SCAN fields per frame
Class Format parameter setting - Video resolution
Description Establishes the number of fields scanned per frame. Set to 1 for progressive
(non-interlaced) scan and 2 for interlaced scan. The SCAN? query returns the current
setting of SCAN.
Command syntax SCAN fields
fields
1 = progressive (non-interlaced)
2 = interlaced
Query syntax SCAN?
Query response fields
Other required
commands
The FMTU command instructs the generator to use the new setting. The ALLU command
updates hardware to the new setting and redraws the test image.
Example
SCAN // Select interlace in buffer
FMTU // Update hardware to current buffer contents
Vista de página 517
1 2 ... 513 514 515 516 517 518 519 520 521 522 523 ... 743 744

Comentários a estes Manuais

Sem comentários