3M Multimedia Projector MP8620 Disassembly/Reassembly
3M 1999 2-5
7
8
9
11
10
12
12
13
7. Remove two (2) screws securing lamp housing cover.
8.
Lift the front of the lamp housing cover up then slide
it forward to remove.
9.
Remove the IR filter. Notice the position of the filter
for reassembly. The fins point downward and out.
10.
Remove light shield by pulling it up and out.
11.
Disconnect two (2) wire connectors from the
thermostat.
12.
Loosen two (2) screws on the white lamp leads and
carefully disconnect wires.
13.
Remove one (1) screw to disconnect two (2) ground
wires.